Water chemistry
Pure water, wastewater, salinity, sulfur, fluoride, heavy metals and solvents require different constructions.
Thirteen XF Series sensors cover general water treatment, fermentation and heat, harsh chemical media, low temperature and pure water. Published values come from the current technical files; conflicting or missing fields remain project confirmation items.
At the same nominal range, reference design, electrolyte, glass membrane, temperature, fouling and mounting determine stability and service life.
Pure water, wastewater, salinity, sulfur, fluoride, heavy metals and solvents require different constructions.
Provide continuous and peak temperature, working pressure and any sterilization cycle.
Confirm immersion, pipe or flow mounting, insertion depth, cleaning and calibration access.
Confirm conventional electrode input, temperature compensation or direct RS485 Modbus output.
Filter by family, then open a detail page to review the full verified specification and selection conditions.
13 models shown
General process & digitalA cost-efficient industrial glass pH electrode for municipal water, wastewater, aquaculture, circulating water and water-treatment equipment.
General process & digitalA double-junction industrial electrode for strong acid and alkali processes, industrial wastewater, electroplating, dyeing and electronics.
General process & digitalA pH electrode with an integrated microprocessor and direct RS485 Modbus RTU communication for water and process monitoring.
Fermentation & high temperatureA refillable large-chamber pH electrode for high-temperature, high-pressure fermentation and heavy-foam processes.
Fermentation & high temperatureA liquid-electrolyte pH sensor for high-temperature fermentation, bioprocess reactors and repeated CIP/SIP service.
Fermentation & high temperatureA high-temperature polymer-gel pH electrode for chemical processes, biotechnology, food, power and semiconductor applications.
Harsh chemical & anti-foulingAn ion-trapping, salt-free-bridge pH electrode for high salinity, heavy metals, organics, ammonium and other media that challenge conventional sensors.
Harsh chemical & anti-foulingA double-ceramic-junction pH electrode with FGD-specific mixed gel for sulfur-rich, high-solids and heavy-metal process conditions.
Harsh chemical & anti-foulingAn industrial pH electrode with an HF-resistant glass membrane for semiconductor, petrochemical, steel wastewater and metal-treatment processes.
Harsh chemical & anti-foulingA junction-free reference design for severely contaminated chlor-alkali, sulfide, high-ammonia, heavy-metal and solvent processes.
Low temperature & pure waterA low-temperature electrolyte pH electrode for frozen brine, surface water, chemical and industrial processes down to -20°C.
Low temperature & pure waterA low-conductivity, high-temperature pH sensor for power generation, boiler water and condensate systems down to 1 μS/cm.
Low temperature & pure waterA refillable pH sensor for ultra-low-conductivity, high-temperature pure water in power, boiler-feed and condensate systems down to 0.2 μS/cm.
| Model | Recommended fit | Temperature | Pressure | Key design |
|---|---|---|---|---|
| XF240Economical industrial pH sensor | Municipal and domestic wastewater | 0–80 °C | 0–2 bar | 0–14 pH |
| XF263General-purpose industrial pH sensor | Strong acid and alkali | 0–100 °C | 0–3 bar, 6 bar max | 0–14 pH |
| XF263iDigital industrial pH electrode | Wastewater treatment | 0–100 °C | 0–3 bar, 6 bar max | 0–14 pH |
| XF232Refillable fermentation pH sensor | Biopharmaceutical fermentation | 0–130 °C | 0–3 bar, 6 bar max | Refillable electrolyte |
| XF263HTHigh-temperature fermentation pH sensor | Biopharmaceutical fermentation | 0–130 °C | 0–3 bar, 6 bar max | Liquid electrolyte |
| XF263THigh-temperature process pH sensor | Chemical and petrochemical | 0–130 °C continuous | 0–3 bar, 6 bar max | Polymer gel |
| XF260EIon-trapping industrial pH electrode | Chlor-alkali and ammonia | 0–130 °C | 0–3 bar, 6 bar max | Ion-trapping system |
| XF264FGD and DeNOx pH sensor | Flue-gas desulfurization | 0–100 °C | 0–3 bar, 6 bar max | FGD-specific mixed gel |
| XF266HF-resistant industrial pH sensor | Semiconductor manufacturing | 0–100 °C | 0–3 bar, 6 bar max | HF-resistant glass |
| XF288Non-porous-junction pH sensor | Chlor-alkali | 0–130 °C | 0–3 bar, 6 bar max | Junction-free reference |
| XF263LLow-temperature pH electrode | Frozen brine | -20–100 °C | 0–3 bar, 6 bar max | -20–100°C |
| XF268High-temperature pure-water pH sensor | Power generation | 0–130 °C | 0–3 bar, 6 bar max | Down to 1 μS/cm |
| XF268 RefillableRefillable ultra-pure-water pH sensor | Power generation | 0–130 °C | 0–3 bar, 6 bar max | Down to 0.2 μS/cm |

MUC-200 is a multiparameter controller, not a pH electrode. It can combine pH with other compatible water-quality sensors and provide a touchscreen, 4–20 mA and Modbus RS485 interfaces.
View MUC-200Send the water chemistry, temperature, pressure, mounting, cable length, controller interface and quantity. We will narrow the choice to one to three suitable models.
Only values found in the current technical files are published. The XF240 junction, XF263i electrical and housing details, and XF266 fluoride conditions still require confirmation on the final configured datasheet.
This page contains only pH electrodes supported by the supplied files. ORP will receive a separate selection page after real models and technical files are available.
We will respond with a recommended configuration, supporting documentation and quotation.