HomeFree / total chlorine selection centerPDCL-700
PDCL-700 controller and black membrane free-chlorine probe
Covered-membrane three-electrode analyzer · PDCL-700

Online Free Chlorine Analyzer

A covered-membrane three-electrode configuration designed to reduce the effect of pH variation and support drinking water, secondary supply, heating, circulating and cooling-water monitoring.

0.05–20.00 mg/LpH 4–9IP68 sensor
Model-specific values checked against the supplied sheet

The five products retain separate principles, ranges, sample limitations and interfaces. Final configuration is controlled by the project confirmation document.

01

Measurement method and product highlights

01

Covered-membrane three-electrode method

02

Membrane design reduces the influence of sample pH fluctuation

03

Fast response and stable digital output

04

Tail aviation connector and documented IP68 sensor protection

05

Three 4–20 mA outputs, three configurable relays and Modbus RS485

02

Verified technical specifications

Confirm the disinfectant, required free or total chlorine result, normal and peak range, sample pH, conductivity, temperature, pressure, flow-cell conditions, calibration method and control interfaces before quotation.

Measurement principle
Covered-membrane three-electrode method
Measurement range
0.05–20.00 mg/L
Resolution
0.01 mg/L
Accuracy
±5% of reading or ±0.05 mg/L, whichever is greater
Sample flow
250–500 mL/min
Operating temperature
0–40°C, non-freezing
Storage temperature
0–50°C
Pressure rating
≤0.3 MPa
Sample pH
4–9
Power supply
85–500 VAC; 9–36 VDC
Analog output
3 × 4–20 mA
Relays
3 configurable relays
Communication
Modbus RS485
Sensor dimensions
Ø30 × 242 mm
Protection
Sensor: IP68 / NEMA6P; transmitter: IP66 / NEMA4X
Weight
Sensor: 750 g; transmitter: 1.35 kg
Cable
3 m
03

Recommended process fit

Drinking-water treatment

Continuous disinfectant-residual monitoring at plant process and outlet points.

Distribution and secondary supply

Verify residual chlorine through distribution networks and secondary-supply facilities.

Cooling and process water

Support disinfectant control in circulating-water and industrial-water systems.

04

Items to confirm before quotation

Confirm the target and water matrix before choosing DPD colorimetry, constant-voltage amperometry, micro-MEMS or a covered-membrane electrode.

  1. 01Disinfectant and free chlorine, total chlorine, chlorine dioxide or active-oxygen target
  2. 02Normal, peak and alarm range plus required detection limit
  3. 03pH, conductivity, temperature, pressure and sample cleanliness
  4. 04Flow-cell conditions, calibration, reagent or membrane maintenance
  5. 05Power, 4–20 mA, relays, Modbus, quantity and destination
05

Project documents available on request

After receiving the operating conditions, we prepare the configured datasheet, flow-cell and mounting confirmation, I/O schedule and quotation. The clean image is not a dimensional drawing.

Get a quote
  • Configured datasheet
  • Sample and mounting confirmation
  • Cable and I/O schedule
  • Project quotation
06

Compare other chlorine models

07

Selection questions

Do all five analyzers use the same measurement method?+

No. CL-201 uses DPD colorimetry; PDCL-400 uses constant-voltage amperometry; PDCL-500M uses a micro-MEMS electrochemical structure; PDCL-700 and PDCL-600 use different membrane-electrode designs.

Can the model be selected only from the range?+

No. Confirm the disinfectant, free or total result, pH, conductivity, temperature, pressure, flow and maintenance method.

Can the product image be used as an installation drawing?+

No. The image provides consistent public presentation. Dimensions, interfaces, accessories and flow cells come from the datasheet and order confirmation.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.

WhatsApp