PDCL-600 controller and gray composite membrane chlorine electrode
Composite digital membrane analyzer · PDCL-600

Free / Total Chlorine and Chlorine Dioxide Analyzer

The broadest documented disinfectant range in this five-model family, using a composite digital membrane electrode with no routine zero calibration and DPD-1 slope calibration.

0.5–200 mg/LpH 4–9DPD-1 slope calibration
Model-specific values checked against the supplied sheet

The five products retain separate principles, ranges, sample limitations and interfaces. Final configuration is controlled by the project confirmation document.

01

Measurement method and product highlights

01

Composite digital membrane electrode for free chlorine, total chlorine or chlorine dioxide configurations

02

Special permeable membrane and antioxidant electrolyte documented for stable measurement

03

No routine zero calibration; slope calibration uses the DPD-1 reference method

04

Integrated automatic linear temperature compensation

05

Three 4–20 mA outputs, three configurable relays and Modbus RS485

02

Verified technical specifications

Confirm the disinfectant, required free or total chlorine result, normal and peak range, sample pH, conductivity, temperature, pressure, flow-cell conditions, calibration method and control interfaces before quotation.

Measurement principle
Composite digital membrane electrode
Measurement ranges
0–2 mg/L; 0–20 mg/L; 0.5–200 mg/L
Sample pH
4–9
Conductivity range
10 µS/cm–50 mS/cm; seawater configuration documented
Flow through cell
250–500 mL/min
Slope drift
Approx. -1% per month
Response time
T90 approx. 2 min
Zero calibration
Not required
Slope calibration
DPD-1 reference method
Temperature compensation
Integrated automatic linear
Materials
PVC-U, stainless steel and microporous hydrophilic membrane
Power supply
85–500 VAC; 9–36 VDC
Analog output
3 × 4–20 mA
Relays
3 configurable relays
Operating temperature
Sample: 0–45°C, non-condensing; ambient: 0–55°C
Communication
Modbus RS485
Sensor dimensions
Ø25 × 205 mm
Cable
5 m
03

Recommended process fit

Drinking-water treatment

Continuous disinfectant-residual monitoring at plant process and outlet points.

Distribution and secondary supply

Verify residual chlorine through distribution networks and secondary-supply facilities.

Cooling and process water

Support disinfectant control in circulating-water and industrial-water systems.

Wastewater disinfection

Track disinfectant residual at disinfection and discharge points when the selected method fits the water matrix.

04

Items to confirm before quotation

Confirm the target and water matrix before choosing DPD colorimetry, constant-voltage amperometry, micro-MEMS or a covered-membrane electrode.

  1. 01Disinfectant and free chlorine, total chlorine, chlorine dioxide or active-oxygen target
  2. 02Normal, peak and alarm range plus required detection limit
  3. 03pH, conductivity, temperature, pressure and sample cleanliness
  4. 04Flow-cell conditions, calibration, reagent or membrane maintenance
  5. 05Power, 4–20 mA, relays, Modbus, quantity and destination
05

Project documents available on request

After receiving the operating conditions, we prepare the configured datasheet, flow-cell and mounting confirmation, I/O schedule and quotation. The clean image is not a dimensional drawing.

Get a quote
  • Configured datasheet
  • Sample and mounting confirmation
  • Cable and I/O schedule
  • Project quotation
06

Compare other chlorine models

07

Selection questions

Do all five analyzers use the same measurement method?+

No. CL-201 uses DPD colorimetry; PDCL-400 uses constant-voltage amperometry; PDCL-500M uses a micro-MEMS electrochemical structure; PDCL-700 and PDCL-600 use different membrane-electrode designs.

Can the model be selected only from the range?+

No. Confirm the disinfectant, free or total result, pH, conductivity, temperature, pressure, flow and maintenance method.

Can the product image be used as an installation drawing?+

No. The image provides consistent public presentation. Dimensions, interfaces, accessories and flow cells come from the datasheet and order confirmation.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.

WhatsApp