HomeFree / total chlorine selection centerPDCL-400
PDCL-400 controller and transparent chlorine flow cell
Constant-voltage amperometric analyzer · PDCL-400

Free Chlorine / Chlorine Dioxide Analyzer

A clean-water flow-cell configuration using constant-voltage amperometric measurement and a replaceable 316 stainless-steel electrode.

0–2 / 0–20 mg/LpH 5–830–60 L/h
Model-specific values checked against the supplied sheet

The five products retain separate principles, ranges, sample limitations and interfaces. Final configuration is controlled by the project confirmation document.

01

Measurement method and product highlights

01

Constant-voltage amperometric measurement

02

Simple flow-cell electrode structure designed for cleaning and replacement

03

Manual or automatic temperature compensation

04

The supplied sheet limits the sample pH to 5–8

02

Verified technical specifications

Confirm the disinfectant, required free or total chlorine result, normal and peak range, sample pH, conductivity, temperature, pressure, flow-cell conditions, calibration method and control interfaces before quotation.

Measurement principle
Constant-voltage amperometry
Measurement ranges
0–2 mg/L; 0–20 mg/L optional
Temperature compensation
Manual or automatic
Temperature coefficient
2%/°C
Sample pH
5–8
Required sample flow
30–60 L/h
Operating temperature
0–50°C, non-freezing
Electrode dimensions
Ø13.5 × 178.5 mm
Mounting thread
PG13.5
Electrode material
316 stainless steel conductor
Cable
5 m standard; extendable to 20 m
03

Recommended process fit

Drinking-water treatment

Continuous disinfectant-residual monitoring at plant process and outlet points.

Distribution and secondary supply

Verify residual chlorine through distribution networks and secondary-supply facilities.

Cooling and process water

Support disinfectant control in circulating-water and industrial-water systems.

04

Items to confirm before quotation

Confirm the target and water matrix before choosing DPD colorimetry, constant-voltage amperometry, micro-MEMS or a covered-membrane electrode.

  1. 01Disinfectant and free chlorine, total chlorine, chlorine dioxide or active-oxygen target
  2. 02Normal, peak and alarm range plus required detection limit
  3. 03pH, conductivity, temperature, pressure and sample cleanliness
  4. 04Flow-cell conditions, calibration, reagent or membrane maintenance
  5. 05Power, 4–20 mA, relays, Modbus, quantity and destination
05

Project documents available on request

After receiving the operating conditions, we prepare the configured datasheet, flow-cell and mounting confirmation, I/O schedule and quotation. The clean image is not a dimensional drawing.

Get a quote
  • Configured datasheet
  • Sample and mounting confirmation
  • Cable and I/O schedule
  • Project quotation
06

Compare other chlorine models

07

Selection questions

Do all five analyzers use the same measurement method?+

No. CL-201 uses DPD colorimetry; PDCL-400 uses constant-voltage amperometry; PDCL-500M uses a micro-MEMS electrochemical structure; PDCL-700 and PDCL-600 use different membrane-electrode designs.

Can the model be selected only from the range?+

No. Confirm the disinfectant, free or total result, pH, conductivity, temperature, pressure, flow and maintenance method.

Can the product image be used as an installation drawing?+

No. The image provides consistent public presentation. Dimensions, interfaces, accessories and flow cells come from the datasheet and order confirmation.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.