HomeFree / total chlorine selection centerCL-201
CL-201 wall-mounted DPD chlorine analyzer with touchscreen
DPD colorimetric analyzer · CL-201

Free / Total Chlorine and Active Oxygen Analyzer

A reagent-based online analyzer for applications that require documented free chlorine, total chlorine or active-oxygen measurement with automatic cleaning and configurable operating modes.

DPD colorimetry0–20 mg/L total chlorine7-inch touchscreen
Model-specific values checked against the supplied sheet

The five products retain separate principles, ranges, sample limitations and interfaces. Final configuration is controlled by the project confirmation document.

01

Measurement method and product highlights

01

DPD standard colorimetric measurement for free chlorine, total chlorine or active oxygen

02

Automatic cleaning reduces routine cell maintenance

03

Continuous or configurable periodic measurement mode

04

Data storage, SD-card export and low-reagent alarm

05

4–20 mA, Modbus RS485, two configurable relays and external-module support

02

Verified technical specifications

Confirm the disinfectant, required free or total chlorine result, normal and peak range, sample pH, conductivity, temperature, pressure, flow-cell conditions, calibration method and control interfaces before quotation.

Measurement principle
DPD colorimetry
Free chlorine range
0–10 mg/L
Free chlorine indication error
0–5 mg/L: ±5% or ±0.03 mg/L, whichever is greater; 5–10 mg/L: ±10%
Free chlorine repeatability
≤5%
Free chlorine detection limit
0.03 mg/L
Total chlorine ranges
0–10 mg/L; 0–20 mg/L
Total chlorine indication error
0–5 mg/L: ±5% or ±0.03 mg/L, whichever is greater; 5–20 mg/L: ±10%
Total chlorine repeatability
≤5%
Total chlorine detection limit
0.03 mg/L
Active oxygen range
0–1 mg/L
Active oxygen indication error
±5% or ±0.02 mg/L, whichever is greater
Active oxygen detection limit
0.005 mg/L
Display
7-inch touchscreen
Calibration
Standard-solution calibration or correction curve
Sample conditions
200–400 mL/min; 0.1–5 bar; 5–40°C
Power supply
220 VAC ±10%, 50/60 Hz; or 24 VDC
Analog output
4–20 mA
Communication
Modbus RS485
Relays
2 configurable relays
Storage temperature
-15–60°C
Storage humidity
10–90%, non-condensing
Dimensions
350 × 177 × 450 mm (W × D × H)
Weight
Approx. 16 kg
Mounting
Wall-mounted
03

Recommended process fit

Drinking-water treatment

Continuous disinfectant-residual monitoring at plant process and outlet points.

Distribution and secondary supply

Verify residual chlorine through distribution networks and secondary-supply facilities.

Cooling and process water

Support disinfectant control in circulating-water and industrial-water systems.

Wastewater disinfection

Track disinfectant residual at disinfection and discharge points when the selected method fits the water matrix.

04

Items to confirm before quotation

Confirm the target and water matrix before choosing DPD colorimetry, constant-voltage amperometry, micro-MEMS or a covered-membrane electrode.

  1. 01Disinfectant and free chlorine, total chlorine, chlorine dioxide or active-oxygen target
  2. 02Normal, peak and alarm range plus required detection limit
  3. 03pH, conductivity, temperature, pressure and sample cleanliness
  4. 04Flow-cell conditions, calibration, reagent or membrane maintenance
  5. 05Power, 4–20 mA, relays, Modbus, quantity and destination
05

Project documents available on request

After receiving the operating conditions, we prepare the configured datasheet, flow-cell and mounting confirmation, I/O schedule and quotation. The clean image is not a dimensional drawing.

Get a quote
  • Configured datasheet
  • Sample and mounting confirmation
  • Cable and I/O schedule
  • Project quotation
06

Compare other chlorine models

07

Selection questions

Do all five analyzers use the same measurement method?+

No. CL-201 uses DPD colorimetry; PDCL-400 uses constant-voltage amperometry; PDCL-500M uses a micro-MEMS electrochemical structure; PDCL-700 and PDCL-600 use different membrane-electrode designs.

Can the model be selected only from the range?+

No. Confirm the disinfectant, free or total result, pH, conductivity, temperature, pressure, flow and maintenance method.

Can the product image be used as an installation drawing?+

No. The image provides consistent public presentation. Dimensions, interfaces, accessories and flow cells come from the datasheet and order confirmation.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.