Normal and peak range
Provide minimum, normal and maximum conductivity instead of a single design value.
Six technical files plus the supplied parameter sheets support a structured catalog for the PEC-500 Series, PEC-500B, digital sensors, online systems, portable measurement and transmitters. Documents without a commercial model remain configured products rather than invented model numbers.
Pure water, process water, wastewater and saline water can differ by several orders of magnitude. Range, cell constant, material, temperature compensation and interface must be confirmed together.
Provide minimum, normal and maximum conductivity instead of a single design value.
Select K value and PP, 316L, titanium or CPVC construction for the range and water chemistry.
Confirm continuous temperature, pressure, thread, insertion, cable and maintenance access.
Conventional probes need a transmitter; digital sensors can integrate through RS485 Modbus.
Named models are presented by model. Word files without model numbers are presented as verified configurations.
Analog sensorsThree analog sensor constructions cover general water treatment and low-to-medium conductivity ranges with different cell constants, materials and mounting threads.
Digital integrationDirect RS485 Modbus output supports long-distance integration without treating the analog and digital sensor configurations as the same product.
Online systemA configured sensor-and-controller system for continuous conductivity and temperature monitoring in water treatment and industrial processes.
Portable measurementA handheld meter and conductivity sensor for field verification, surface water, wastewater, aquaculture, boiler water and laboratory sampling.
TransmittersTwo panel-mounted configurations provide continuous conductivity and temperature display, analog transmission, Modbus communication and alarm control.
| Product group | Primary range | Interface / output | Recommended fit | Verified configurations |
|---|---|---|---|---|
| PEC-500 / 500E / 500FAnalog Conductivity Sensor Series | 10–5000 µS/cm (K=1.0) | K=0.01–1.0 | Water treatment | 3 |
| PEC-500B + Digital ECDigital Conductivity Sensors | 10 µS/cm–200 mS/cm | RS485 Modbus / Modbus RTU | Remote water stations | 2 |
| Configured online systemOnline Conductivity Analyzer | Conductivity: 10–5000 µS/cm; temperature: 0–80°C | 3 × 4–20 mA; Modbus RS485 | Municipal water | 1 |
| Portable configurationPortable Conductivity Analyzer | 0–20000 µS/cm (K=1) | IP67 / IP68 | Field verification | 1 |
| 2.4-inch / 2.8-inchSingle-Parameter Conductivity Transmitter | K=1.0: 2–2000 µS/cm; K=10.0: 20–20000 µS/cm | 1 × isolated 4–20 mA; Modbus RS485 | Local panels | 2 |
Smart water management, an unmanned boat, a wastewater plant, a river corridor and an industrial pumping station—with third-party company branding removed from the public copy.
View five project records↗
2022 · Zhejiang, China · XiaoshanConductivity was one of the online indicators used to track changes in dissolved ionic content and support anomaly detection.
↗
2022 · Guangdong, China · YangjiangConductivity was combined with pH, dissolved oxygen, turbidity, ammonia and UV COD to create a mobile water-condition profile.
↗
2021 · Hebei, China · HengshuiConductivity tracked ionic-content trends and was interpreted together with organic load, ammonia and dissolved oxygen.
↗Different water matrices can span several orders of magnitude. Minimum, normal and maximum values are needed first.
No. Their range, cell constant, material, temperature compensation and mounting threads differ.
No. The supplied records show different materials, power, ranges and dimensions, so they remain separate digital configurations.
No. Public copy retains project context, deployment and verified parameters without third-party company names or branding.
We will respond with a recommended configuration, supporting documentation and quotation.