Transmitters · 2.4-inch / 2.8-inch

Single-Parameter Conductivity Transmitter

Two panel-mounted configurations provide continuous conductivity and temperature display, analog transmission, Modbus communication and alarm control.

4–20 mAModbus RS4852 alarm relays
Structured from the supplied technical files

Only values confirmed in the current records are published. Products without a commercial model remain configured products; final range, cell constant, material, interface and accessories are controlled by the project datasheet.

01

Construction and product highlights

01

K=1.0 and K=10.0 electrode ranges

02

Manual or automatic temperature compensation

03

One isolated 4–20 mA output

04

Modbus RS485 communication

05

Two alarm relays with high/low and hysteresis settings

06

Panel-mounted IP54 enclosure

02

Verified technical specifications

No commercial model number is present in the two supplied transmitter files. Confirm display size, accuracy, dimensions and sensor interface before quotation.

Measuring range
K=1.0: 2–2000 µS/cm; K=10.0: 20–20000 µS/cm
Output / communication
1 × isolated 4–20 mA; Modbus RS485
Temperature compensation
-10–130°C; manual / automatic; NTC10K or PT1000
Mounting
Panel mounting; IP54, indoors or inside an instrument enclosure
03

Configuration and model comparison

2.4-inch configuration Panel conductivity transmitter
2.4-inch configuration

Panel conductivity transmitter

2.4-inch LCD±1.5% FSIP54
Measuring range
K=1.0: 2–2000 µS/cm; K=10.0: 20–20000 µS/cm
Accuracy / linear error
±1.5% FS
Temperature compensation
-10–130°C; manual / automatic; NTC10K or PT1000
Display
2.4-inch monochrome LCD, 128 × 64
Power
220 VAC ±10%, 50/60 Hz
Output / communication
1 × isolated 4–20 mA; Modbus RS485
Relays
2 alarm relays
Protection
IP54
Dimensions
97 × 97 × 130 mm; panel cutout 92.5 × 92.5 mm
2.8-inch configuration Panel conductivity transmitter
2.8-inch configuration

Panel conductivity transmitter

2.8-inch LCD±2% FSIP54
Measuring range
K=1.0: 2–2000 µS/cm; K=10.0: 20–20000 µS/cm
Accuracy / linear error
±2% FS
Temperature compensation
-10–130°C; manual / automatic; NTC10K or PT1000
Display
2.8-inch monochrome LCD, 128 × 64
Power
220 VAC ±10%, 50/60 Hz
Output / communication
1 × isolated 4–20 mA; Modbus RS485
Relays
2 alarm relays
Protection
IP54
Dimensions
100 × 100 × 150 mm
04

Recommended applications

Local panels

Display conductivity and temperature at a process panel.

Alarm control

Use high/low relays and hysteresis for process response.

PLC integration

Send isolated 4–20 mA or Modbus RS485 to the control system.

Water treatment skids

Integrate a compact conductivity transmitter into treatment equipment.

05

Items to confirm

No commercial model number is present in the two supplied transmitter files. Confirm display size, accuracy, dimensions and sensor interface before quotation.

  1. 01Minimum, normal and maximum conductivity
  2. 02Water chemistry, temperature and pressure
  3. 03Cell constant, wetted material and mounting thread
  4. 04Cable, power, 4–20 mA or RS485 Modbus
06

Parameter sources

These files support the published data. Third-party company branding in source material is not presented on the public page.

Get a quote
  • 单参数电导率变送器.docx
  • 单参数电导率变送器(新).docx
07

Related conductivity products

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.

WhatsApp