HomeParametersSuspended solids / sludge selection
SS / MLSS · Online optical measurement

Select suspended-solids and sludge-concentration measurement by process and range

PSS-800 and PSS-600 now have independent records built from their supplied sheets. Both support continuous monitoring, but their ranges, accuracy, dimensions and recommended process fit are different.

2verified product detail pages
0.01 mg/Llowest documented start
120000 mg/Lhighest documented range
9real project records
01 · Start with the target

Confirm SS, MLSS or sludge concentration first

The same mg/L value represents very different conditions in an aeration basin, return sludge, plant outlet or industrial discharge. Particle distribution, bubbles, velocity and cleaning must be confirmed together.

01

Measurement target

Identify suspended solids, mixed-liquor suspended solids or concentrated sludge and state the process point.

02

Minimum, normal and peak

Provide minimum, normal, peak and alarm mg/L—not a single design value.

03

Homogeneity and mounting

Confirm sludge homogeneity, bubbles, settling, pressure, velocity, immersion depth and mounting space.

04

Maintenance and interface

Confirm automatic cleaning, material, maintenance interval, cable, 4–20 mA, relays and RS485.

02 · Model architecture

PSS-800 wide range + PSS-600 compact sensor

Each page retains its own range, accuracy, dimensions, material, protection and interface evidence.

PSS-800 transmitter and stainless suspended-solids sensorWide-range optical analyzer
PSS-800Wide-Range Suspended Solids / Sludge Analyzer

The broadest documented concentration coverage in the two-model PSS family, using combined infrared absorption and dual-beam scattered-light measurement with standard or seawater construction.

0.01–120000 mg/L±5% of reading≤2.5 m/s
03 · Applications

Nine real suspended-solids and sludge projects

Public images remove the original Chinese information panels and third-party branding. All English-site case copy is searchable English.

View full cases
Online analyzer cabinets and outdoor monitoring boxes at Chengxi wastewater treatment plant2020 · Zhao’an, Zhangzhou, Fujian, China

Chengxi wastewater plant online monitoring upgrade

In December 2020, online analyzers were installed for continuous wastewater monitoring, including suspended solids / sludge concentration alongside organic and nutrient parameters and dissolved oxygen.

Monitored parametersSuspended solids / sludgeCOD / organic loadAmmonia nitrogenTotal phosphorusTotal nitrogenDissolved oxygenLiquid level
Urban drainage channel and automatic water-quality monitoring cabinets2019 · Ningde, Fujian, China

24-hour urban drainage-channel water-quality monitoring

In November 2019, water was pumped to a bank-side station where a multiparameter controller combined transparency, suspended solids and other sensors for continuous monitoring.

Monitored parametersSuspended solidsTransparencyTotal phosphorusAmmonia nitrogenMultiparameter station
Wastewater plant entrance and stainless analyzer enclosures at an aeration basin2019 · Baoding, Hebei, China

Hancunhe wastewater plant capacity upgrade

In May 2019, continuous analyzers were installed for dissolved oxygen, ORP and suspended solids / sludge concentration to support process operation and outlet compliance.

Monitored parametersSuspended solids / sludgeDissolved oxygenORP
Two online analyzer cabinets and industrial wastewater treatment buildings2021–2024 · Linyi, Shandong, China

Recurring industrial wastewater monitoring service

From 2021 through 2024, repeated project deliveries combined automatic sampling and online analysis for key wastewater indicators, including suspended solids.

Monitored parametersSuspended solidsCODcrTotal phosphorusAutomatic sampling
Compact automatic water-quality station beside a river and flood-control embankment2023 · Bengbu, Anhui, China

Huai River flood-control hub water-quality station

In November 2023, high-accuracy instruments were installed at key locations and linked through data acquisition to an automation center for real-time water-quality observation.

Monitored parametersSuspended solidsPermanganate indexAutomatic station
Stainless analyzer enclosure mounted beside a municipal wastewater aeration basin2017 · Meishan, Sichuan, China

Meishan municipal wastewater plant upgrade

In October 2017, online dissolved-oxygen and suspended-solids / sludge-concentration analyzers were installed to record key process changes continuously.

Monitored parametersSuspended solids / sludgeDissolved oxygen
Rows of white online analyzers in a wastewater plant monitoring room2021 · Fengxiang, Shaanxi, China

Wastewater plant influent and effluent monitoring

In December 2021, online analyzers were installed at plant influent and outlet points to measure, analyze and transmit the principal water-quality indicators.

Monitored parametersSuspended solids / sludgepHAutomatic samplingData acquisition
Coal-mine wastewater monitoring building and online analyzer cabinets2021 · China

Coal-mine wastewater discharge monitoring

In May 2021, an automatic pollution-source monitoring system was installed at the discharge outlet to track treated wastewater conditions continuously.

Monitored parametersSuspended solidsCODcrAmmonia nitrogenAutomatic sampling
Brand-neutral rural wastewater monitoring room with online analyzer cabinets and control panel in Wuzhishan2021 · Wuzhishan, Hainan, China

Rural wastewater influent monitoring in Wuzhishan

In July 2021, online water-quality instruments were installed at the wastewater-treatment influent to collect, monitor and transmit changing inlet conditions continuously, with early warning when measurements exceeded control limits.

Monitored parametersSuspended solids / sludgeTotal phosphorusAutomatic samplingData acquisition and transmission
04 · Common questions

Confirm this information before an inquiry

How should I choose PSS-800 or PSS-600?+

Start with PSS-800 for high-concentration or very wide-range duty. Compare PSS-600 when a slimmer sensor fits the installation and the range remains within its documented limits.

Can I select only by maximum range?+

No. Normal value, particle homogeneity, bubbles, pressure, velocity, cleaning and mounting structure also matter.

Do both products have the same outputs?+

Both supplied sheets list three 4–20 mA outputs, three relays and Modbus RS485, but final project wiring remains subject to order confirmation.

Can the images replace technical drawings?+

No. The clean images are for consistent public presentation. Dimensions and accessories come from the verified specifications and project confirmation.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.

WhatsApp