HomeSuspended solids / sludge selection centerPSS-800
PSS-800 transmitter and stainless suspended-solids sensor
Wide-range optical analyzer · PSS-800

Wide-Range Suspended Solids / Sludge Analyzer

The broadest documented concentration coverage in the two-model PSS family, using combined infrared absorption and dual-beam scattered-light measurement with standard or seawater construction.

0.01–120000 mg/L±5% of reading≤2.5 m/s
Model-specific values checked against the supplied sheet

PSS-800 and PSS-600 retain separate ranges, accuracy, dimensions and process fit. Final configuration is controlled by the project confirmation document.

01

Measurement principle and product highlights

01

Combined infrared absorption and dual-beam scattered-light ratio measurement

02

The supplied sheet references the ISO 7027 infrared method to reduce sample-color influence

03

Built-in self-diagnostics and optional automatic cleaning

04

Digital sensor output supports long-distance transmission and project integration

05

Automatic cleaning can be selected to reduce optical-window maintenance

06

Reverse-polarity protection is provided for sensor power and RS485 A/B wiring

07

Three 4–20 mA outputs, three configurable relays and Modbus RS485

08

Time display, data storage, historical-data review and optional wireless transmission

02

Verified technical specifications

Confirm whether the target is suspended solids, mixed liquor or sludge concentration; provide minimum, normal and peak mg/L, sludge homogeneity, process point, pressure, velocity, cleaning, material, cable and control interfaces before quotation.

Measurement principle
Combined infrared absorption and dual-beam scattered light
Measurement range
0.01–20000 mg/L; 0.01–45000 mg/L; 0.01–120000 mg/L
Accuracy
±5% of reading; dependent on sludge homogeneity
Repeatability
±2%
Resolution
0.01–1 mg/L, depending on range
Pressure rating
≤0.4 MPa
Maximum flow velocity
≤2.5 m/s (8.2 ft/s)
Calibration
Sample calibration; slope calibration
Construction
SUS316L standard; titanium-alloy seawater version; PUR cable
Power supply
85–500 VAC; 9–36 VDC
Analog output
3 × 4–20 mA
Relays
3 configurable relays
Digital communication
Modbus RS485
Storage temperature
-15–50°C
Operating temperature
0–45°C, non-freezing
Sensor dimensions
Ø60 × 261 mm
Transmitter dimensions
145 × 125 × 162 mm
Sensor weight
1.65 kg
Transmitter weight
1.35 kg
Sensor protection
IP68 / NEMA6P
Transmitter protection
IP66 / NEMA4X
Cable
10 m standard; extendable to 100 m
03

Recommended process fit

Activated-sludge process

Track mixed-liquor and sludge concentration through biological-treatment stages.

Secondary clarification

Monitor solids trends for settling, return-sludge and excess-sludge decisions.

Industrial wastewater

Measure suspended-solids changes in industrial treatment and discharge projects.

Municipal outlet and networks

Add continuous solids monitoring to plant outlets, drainage channels and network stations.

04

Items to confirm

First identify whether the target is suspended solids, mixed liquor or sludge concentration, then confirm normal, peak and installation conditions.

  1. 01Minimum, normal, peak and alarm concentration
  2. 02Aeration basin, return sludge, clarifier, outlet or industrial discharge point
  3. 03Sludge homogeneity, bubbles, coating, cleaning and maintenance interval
  4. 04Pressure, velocity, material, cable, 4–20 mA, relays and RS485
05

Project documents available on request

After receiving the operating conditions, we prepare the configured datasheet, installation confirmation, I/O schedule and quotation. The clean product image is not a dimensional drawing.

Get a quote
  • Configured model datasheet
  • Mounting and cleaning confirmation
  • Cable and I/O schedule
  • Project quotation
06

Compare the other PSS model

07

Selection questions

What is the main difference between PSS-800 and PSS-600?+

PSS-800 provides wide-range configurations up to 120000 mg/L. PSS-600 uses a slimmer sensor and has a documented upper range of 50000 mg/L.

Why does sludge homogeneity affect accuracy?+

Optical results are influenced by particle distribution, bubbles and sludge homogeneity, so selection must confirm both range and the real process point.

Can the product image be used as a dimensional drawing?+

No. It provides consistent public presentation. Dimensions, interfaces, accessories and mounting come from the datasheet and order confirmation.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.