Home›Products›PMI800 Series
FUNEL PMI800 Series portable water quality analyzer
FUNEL portable water analysis platform

PMI800 Series Portable Water Quality Analyzer Platform

One handheld platform covers eight interchangeable measurement options: pH, ORP, conductivity, dissolved oxygen, turbidity, suspended solids, chlorophyll-a and blue-green algae. Each model has its own specifications page and quotation path.

Eight models cover pH, ORP, conductivity, dissolved oxygen, turbidity, suspended solids, chlorophyll-a and blue-green algae3.5-inch adjustable-backlight color display with automatic sensor recognition and adaptive reading screenMore than 100,000 stored records with USB export
01 · Choose by parameter

Eight PMI800 portable water analyzers

Each model pairs the handheld host with a dedicated probe. Images, models, ranges, resolutions and accuracy values follow the supplied technical files; open a card for the complete specifications.

8 models shown

PMI800-pH portable water analysis probeElectrochemical
PMI800-pHPortable pH Water Analyzer

Portable pH measurement with a dedicated glass-electrode sensor and automatic host recognition.

Measurement rangepH 0–14; temperature 0–60°C
Resolution0.01 pH; 0.01°C
Accuracy±0.1 pH; temperature ±0.5°C
PMI800-ORP portable water analysis probeElectrochemical
PMI800-ORPPortable ORP Water Analyzer

Portable oxidation-reduction potential measurement for field verification and process checks.

Measurement range−2000 to +2000 mV
Resolution1 mV
Electronic accuracy±2 mV
PMI800-EC portable water analysis probeElectrochemical
PMI800-ECPortable Conductivity Water Analyzer

Portable conductivity measurement with a parameter-specific probe and logged field readings.

Measurement range0–20,000 μS/cm (K=1)
Resolution0.1 μS/cm–0.01 mS/cm, depending on range
Accuracy±1.5% or ±2 μS/cm, whichever is greater
PMI800-FDO portable water analysis probeOptical & solids
PMI800-FDOPortable Fluorescence Dissolved Oxygen Meter

Fluorescence dissolved-oxygen measurement without a membrane or electrolyte replacement routine.

Measurement range0–20 mg/L or 0–200% saturation; temperature 0–45°C
Resolution0.01 mg/L
Accuracy±3% or ±0.3 mg/L, whichever is greater; temperature ±0.5°C
PMI800-TU portable water analysis probeOptical & solids
PMI800-TUPortable Turbidity Water Analyzer

Portable turbidity measurement for drinking water, surface water and treatment verification.

Measurement range0.1–1000 NTU
Accuracy±5% of reading or ±0.3 NTU, whichever is greater
Resolution0.01–0.1 NTU, depending on range
PMI800-SS portable water analysis probeOptical & solids
PMI800-SSPortable Suspended Solids / Sludge Analyzer

Portable suspended-solids and sludge-concentration measurement with selectable sensor ranges.

Selectable measurement ranges0.01–20,000; 0.01–45,000; or 0.01–120,000 mg/L
Accuracy±5% of reading, dependent on sludge homogeneity
Resolution0.01–1 mg/L, depending on range
PMI800-CH portable water analysis probeAlgae monitoring
PMI800-CHPortable Chlorophyll-a Water Analyzer

Portable chlorophyll-a measurement for lakes, reservoirs, aquaculture and field surveys.

Measurement range0–500 μg/L
Resolution0.01 μg/L
Documented accuracy reference±5% of the signal level corresponding to 1 ppb Rhodamine B dye
PMI800-BA portable water analysis probeAlgae monitoring
PMI800-BAPortable Blue-Green Algae Water Analyzer

Portable blue-green algae measurement for bloom investigation and water-body surveys.

Measurement range0–300,000 cells/mL
Resolution20 cells/mL
Documented accuracy reference±10% of the signal level corresponding to 1 ppb Rhodamine B dye
02

Portable host and parameter sensor

01

Eight models cover pH, ORP, conductivity, dissolved oxygen, turbidity, suspended solids, chlorophyll-a and blue-green algae

02

3.5-inch adjustable-backlight color display with automatic sensor recognition and adaptive reading screen

03

More than 100,000 stored records with USB export

04

IP67 host powered by four 3.7 V rechargeable lithium batteries

05

Each model has its documented range, accuracy, sensor construction and protection on a dedicated page

03

Product technical specifications

Order code
CJ-PMI800 Series
Measurement options
pH, ORP, conductivity, dissolved oxygen, turbidity, suspended solids, chlorophyll-a and blue-green algae
Sensor recognition
Automatic sensor-type recognition and adaptive reading screen
Configuration
Parameter setting and calibration from the handheld host
Display
3.5-inch color display with adjustable backlight
Power supply
4 × 3.7 V rechargeable lithium batteries
Data storage
>100,000 records
Data export
USB
Host material
ABS + PC
Host protection
IP67
Operating temperature
0–50°C, non-freezing
Storage temperature
−15 to 60°C
Host size and weight
203 × 100 × 43 mm; 0.5 kg
Standard configuration
Final configuration is confirmed during quotation.
Optional configuration
Final configuration is confirmed during quotation.
Consumables
Final configuration is confirmed during quotation.
04

Recommended portable measurement tasks

Core electrochemistry

Use for rapid measurements, logged readings and result verification in the real water and field conditions.

Optical field measurement

Use for rapid measurements, logged readings and result verification in the real water and field conditions.

Solids and sludge

Use for rapid measurements, logged readings and result verification in the real water and field conditions.

Algae monitoring

Use for rapid measurements, logged readings and result verification in the real water and field conditions.

05

Confirm the water and sensor before selection

The PMI800 host platform is shared, while the sensor, range, calibration and suitable water differ by model. The order code is CJ-PMI800 Series. Unlisted standard items, options and consumables use “Final configuration is confirmed during quotation.”

  1. 01Confirm the target parameter and normal/peak range
  2. 02Confirm the water matrix, turbidity, sludge homogeneity or algae distribution
  3. 03Confirm field measurement, laboratory verification or online-instrument comparison
  4. 04Confirm cable, quantity, destination and delivery requirement
06

Technical and quotation documents

The page values are structured from the supplied PMI800 technical files. After confirming the model and use conditions, we can prepare a neutral English datasheet, configuration confirmation and quotation.

Share your project requirement
  • Neutral English technical datasheet→
  • Sensor and host configuration confirmation→
  • Calibration and field-use guidance→
  • Project quotation→

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.

Email WhatsApp