HomeChlorophyll-a selection centerPCH-800A
PCH-800A black FUNEL transmitter and stainless chlorophyll-a sensor
Fluorescence chlorophyll analyzer · PCH-800A

Online Chlorophyll-a Analyzer

A reagent-free fluorescence sensor for continuous chlorophyll-a measurement. Selection must consider spatial variation in algae and the documented turbidity condition below 50 NTU.

0–500 µg/L0.01 µg/LTurbidity <50 NTU
Values checked item by item against the PCH-800A source

Range, accuracy wording, turbidity condition, construction, dimensions and interfaces are stored separately. The black transmitter image is the approved FUNEL export presentation; final configuration remains subject to project confirmation.

01

Measurement principle and product highlights

01

Chlorophyll-a fluorescence measurement for assessing algal abundance in water

02

No reagent or sample pretreatment is required for rapid continuous measurement

03

Digital sensor output supports long-distance transmission and project integration

04

Plug-and-play field installation with reverse-polarity protection for sensor power and RS485 wiring

05

Three 4–20 mA outputs, three configurable relays and Modbus RS485

06

Time display, data storage, historical-data review and optional wireless transmission

02

Verified technical specifications

Before quotation, provide the monitoring objective, water matrix, expected chlorophyll range, normal and peak turbidity, number of monitoring points, pressure, material, mounting, cable, power, outputs and destination.

Measurement principle
Chlorophyll-a fluorescence
Measurement range
0–500 µg/L
Accuracy
±5% of the signal level corresponding to a 1 ppb rhodamine B sample
Repeatability
±3%
Resolution
0.01 µg/L
Pressure rating
≤0.4 MPa
Calibration
Offset calibration; slope calibration
Water-condition note
Chlorophyll may be non-uniformly distributed; multipoint monitoring is recommended; turbidity <50 NTU
Sensor construction
SUS316L standard version; titanium-alloy seawater version; POM end covers; PUR cable
Power supply
85–500 VAC; 9–36 VDC
Analog output
3 × 4–20 mA
Relays
3 configurable relays
Digital communication
Modbus RS485
Storage temperature
-15–50°C
Operating temperature
0–45°C, non-freezing
Sensor dimensions
Ø30 × 223 mm
Transmitter dimensions
145 × 125 × 162 mm
Sensor weight
0.55 kg
Transmitter weight
1.35 kg
Sensor protection
IP68 / NEMA6P
Transmitter protection
IP66 / NEMA4X
Cable
10 m standard; extendable to 100 m
03

Source-supported applications

Water-source monitoring

Track chlorophyll trends at raw-water sources and water-plant intakes.

Aquaculture

Observe algal abundance in ponds, recirculating systems and aquaculture water.

Surface and landscape water

Add continuous chlorophyll measurement to lakes, rivers and managed landscape water.

Seawater projects

Use the documented titanium-alloy construction option when seawater compatibility is required.

04

Items to confirm

Online chlorophyll selection requires more than a range: turbidity, spatial distribution, point count and the actual water matrix must also be confirmed.

  1. 01Monitoring objective, water matrix and expected algal change
  2. 02Minimum, normal and peak chlorophyll plus turbidity
  3. 03Stratification, representativeness and number of monitoring points
  4. 04Pressure, standard or seawater material, mounting and maintenance access
  5. 05Cable, power, 4–20 mA, relays and Modbus RS485
05

Project documents available on request

Based on the water body, range, turbidity, material and point requirements, we provide a configured datasheet, point and mounting confirmation, I/O schedule and project quotation with the supply scope itemized.

Get a quote
  • Configured datasheet
  • Point and mounting confirmation
  • Cable and I/O schedule
  • Project quotation
06

Selection questions

Does PCH-800A require reagents?+

The supplied sheet describes fluorescence chlorophyll measurement without reagents or sample pretreatment.

Why does the source require turbidity below 50 NTU?+

This is the documented water-condition limit. Higher-turbidity samples require project review and cannot automatically use the standard condition.

Why is accuracy referenced to rhodamine B signal?+

The source expresses accuracy against the signal level of a 1 ppb rhodamine B sample. The page preserves that wording rather than converting it into an unsupported percentage of reading.

Can the website image replace a technical drawing?+

No. The clean image is for public presentation. Sensor dimensions, transmitter dimensions and mounting remain controlled by the datasheet and order confirmation.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.

WhatsApp