Up to eight simultaneous measurements in one body, reducing wiring and deployment compared with separate instruments

MP301 Integrated Multiparameter Water Quality Analyzer
MP301 combines sensors, data acquisition, storage and Modbus RS485 in one pressure-rated probe body. The HDC-100A handheld supports field viewing, configuration, calibration and export. The final electrode set is confirmed for the real water and objective.
Integrated probe and field-handheld capability
IP68 main unit, Ø90 × 635 mm, with a documented maximum pressure depth of 30 m
Supports pH, ORP, conductivity, turbidity, fluorescence DO, chlorophyll, blue-green algae and multiple ion-selective electrodes
Modbus RS485 as standard with an optional Bluetooth handheld for field setup and readings
HDC-100A handheld with 3.5-inch color display, IP67 protection and more than 100,000 stored records
Can be integrated with battery, solar or mains-powered systems after project confirmation
Product technical specifications
- Simultaneous parameters
- Up to 8
- Main-unit power
- 9–36 VDC; 3 W
- Communication
- Modbus RS485; optional Bluetooth handheld link
- Protection
- Main unit IP68; handheld IP67
- Main-unit size
- Ø90 × 635 mm
- Main-unit weight
- 5 kg
- Maximum pressure depth
- 30 m; 10 m when ion-selective electrodes are fitted
- HDC-100A handheld
- 3.5-inch color display; >100,000 records; IP67; 203 × 100 × 43 mm; 0.5 kg
- pH
- 0–14 pH; 0.01 pH; ±0.1 pH
- ORP
- −1000 to +1000 mV; 1 mV; ±5 mV
- Conductivity
- 10 μS/cm–200 mS/cm; ±1% or ±1 μS/cm, whichever is greater
- Turbidity
- 0–1000 NTU; 0.1 NTU; ±5% or ±0.3 NTU, whichever is greater
- Dissolved oxygen
- 0–20 mg/L or 0–200% saturation; 0.01 mg/L; ±3% or ±0.3 mg/L
- Chlorophyll-a
- 0–500 μg/L
- Blue-green algae
- 0–300,000 cells/mL
- Ammonia nitrogen
- 0.1–3000 mg/L-N
- Nitrate nitrogen
- 0.5–3000 mg/L-N
- Other ion-selective options
- Chloride 3–3500 mg/L; fluoride 0.5–10,000 mg/L; potassium 0.5–5000 mg/L
Recommended multiparameter field tasks
Groundwater and wells
Collect depth, temperature and multiparameter profiles at monitoring wells and groundwater points.
Rivers, lakes and reservoirs
Combine core water quality, algae and nutrient measurements for fixed-point or mobile surveys.
Water and wastewater treatment
Support process verification, commissioning, troubleshooting and multi-point field comparison.
Research and project integration
Connect through Modbus RS485 to data loggers, buoys, solar systems or monitoring platforms.
Two real groundwater multiparameter projects
Project records are published as searchable webpage text, with public case visuals standardized in English under the FUNEL brand.
View full cases↗
2020 · Changyi, Shandong, ChinaGroundwater monitoring station program
In 2020, monitoring equipment was deployed with the Changyi water-resources program to collect, analyze and transmit groundwater data from multiple sites.
2022 · Urumqi, Xinjiang, ChinaGroundwater pollution monitoring pilot
In May 2022, automatic monitoring equipment was installed at existing points to track groundwater quality and water-level changes dynamically.
What to confirm before selecting the electrode set
Up to eight parameters describes platform capability; it does not mean every electrode is supplied as standard. Ion-selective electrodes also change the documented maximum depth. Water matrix, ranges, depth, calibration, interferences, power and communications must be reviewed before quotation.
- 01Confirm parameters, minimum/normal/maximum values and simultaneous channel count
- 02Confirm depth, pressure, temperature, velocity, fouling and cleaning conditions
- 03Confirm handheld, logger, Modbus, Bluetooth and supervisory interfaces
- 04Confirm cable, power, solar supply, mounting and field-maintenance method
Documents prepared after configuration review
After receiving the water matrix and parameter schedule, we can prepare a neutral datasheet, electrode compatibility matrix, wiring and communication schedule, calibration and maintenance recommendation, and quotation.
Share your project requirement- Neutral technical datasheet→
- Electrode and range compatibility matrix→
- Wiring, communication and power confirmation→
- Calibration, maintenance and project quotation→
Tell us what you need to measure.
We will respond with a recommended configuration, supporting documentation and quotation.