Range and optical path
Provide minimum, normal and maximum NO₃-N and confirm the 1 mm or 2 mm optical path.
Select direct-immersion 210 nm UV spectral nitrate measurement for drinking water, source water, industrial process water and wastewater treatment.
PUVNO3-900 measures nitrate nitrogen by 210 nm UV spectral absorption without chemical reagents. Selection must include the expected range, 1 mm or 2 mm optical path, turbidity, solids, fouling, cleaning, pressure and mounting conditions.
Provide minimum, normal and maximum NO₃-N and confirm the 1 mm or 2 mm optical path.
State drinking water, surface water, industrial process water or wastewater plus turbidity and solids.
Confirm pressure, immersion position, automatic cleaning and maintenance access.
Confirm cable, power, 4–20 mA, relays, RS485, quantity and destination.

Reagent-free direct-immersion 210 nm UV absorption for continuous nitrate nitrogen measurement.
Verifizierte DatenThe supplied sheet states 0.1–100.0 mg/L for the 1 mm path and 0.1–50.0 mg/L for the 2 mm path.
No. PUVNO3-900 uses direct-immersion 210 nm UV spectral absorption without chemical reagents.
We will respond with a recommended configuration, supporting documentation and quotation.