01 · 2020 · Zhao’an, Zhangzhou, Fujian, China
Municipal wastewater plant multi-parameter monitoring upgrade
- Project background
- The Chengxi wastewater-treatment project was documented with a total investment of CNY 200 million, a treatment scale of 125,000 tonnes per day and a Class 1A discharge objective. The monitoring system formed part of the regional wastewater-management program.
- Implementation
- In December 2020, multiple online analyzers were installed to provide continuous organic-load, nutrient, solids and process measurements for plant operation.
- Monitored parameters
- UV254 / COD correlationAmmonia nitrogenTotal phosphorusTotal nitrogenSuspended solidsDissolved oxygenLiquid level
- UV254 configuration
- PUVCOD-900 supplied direct-immersion UV254 organic-load measurement within the multi-parameter analyzer system.
- Project role
- The integrated station provided continuous process visibility for routine operation and environmental management.