One-stop instrumentation for liquid-cooled data centers
A project-facing instrumentation path for CDU systems, load banks and cold-plate flow and thermal-resistance testing.
Flow
Temperature
Coolant qualityThe system in one paragraph
FUNEL helps EPC contractors, MEP contractors, CDU integrators and equipment OEMs coordinate the instrumentation package around the actual liquid-cooling circuit. Public information here shows the application scope and product paths; detailed system drawings, full model combinations and project quotations are prepared after the project requirements are reviewed.
Inputs required before model selection.
Project role
EPC, MEP contractor, CDU integrator, test-equipment builder or OEM
Application
CDU integrated system, load bank, cold-plate flow test or thermal-resistance validation
Monitoring points
Flow, pressure, supply and return temperature, pH, conductivity and turbidity
Integration
Pipe size, media, pressure, temperature, installation, power and 4–20 mA / RS485 / Modbus requirements
Connect each point to an operating decision.
Design the measurement, installation and data path together.
Define the project circuit
Share the P&ID, CDU layout, test-bench drawing or monitoring-point list so instrument locations can be reviewed against the actual circuit.
Match each measurement
Select flow, pressure, temperature and liquid-analysis instruments from the required range, media, installation and signal interface.
Coordinate the package
FUNEL can consolidate the agreed models, accessories, interfaces and documentation into one project quotation.
Keep detailed design controlled
Full wiring, detailed model combinations and project-specific selection tables are released after the application and customer are confirmed.
Choose the project path before selecting the product combination.

CDU Integrated System Solution
Primary and secondary loop monitoring.

Data Center Load Bank Solution
Validation points for simulated CPU or rack-loop circuits.

Cold Plate Flow and Thermal Resistance Test Solution
Flow, differential pressure and thermal-resistance validation.
CDU Integrated System Solution
Products for primary and secondary loop monitoring.

Electromagnetic flowmeter
Flow measurement

Compact pressure transmitter
CDU inlet and outlet pressure

Integrated compact temperature transmitter
Supply and return temperature

Temperature and humidity transmitters
Temperature and ambient humidity

Digital liquid-analysis sensors
pH, conductivity and turbidity

Analog liquid-analysis instruments
Analog conductivity and pH

Pressure-retaining turbidity instrument
Pressure-retaining turbidity
Data Center Load Bank Solution
Products for simulated CPU or rack-loop validation.

Turbine and vortex flowmeters
Compact coolant-loop flow measurement

Compact pressure transmitter
CDU inlet and outlet pressure

Integrated compact temperature transmitter
Supply and return temperature
Cold Plate Flow and Thermal Resistance Test Solution
Products for flow, differential pressure, temperature and coolant-quality validation.

Electromagnetic flowmeter
Flow measurement

Compact pressure transmitter
CDU inlet and outlet pressure

Integrated compact temperature transmitter
Supply and return temperature

Digital liquid-analysis sensors
pH, conductivity and turbidity

Pressure-retaining turbidity instrument
Pressure-retaining turbidity
Questions to resolve before quotation.
Who is this solution intended for?+
It is intended for data-center EPC contractors, MEP contractors, CDU integrators, test-equipment builders and OEMs that need a coordinated instrumentation package.
Can I receive the complete selection table immediately?+
The public page shows the application and product paths. Detailed drawings, complete model combinations and project quotations are prepared after the project requirements are reviewed.
What should I send for a project quotation?+
Send the P&ID or system drawing, media, pipe size, flow, pressure, temperature, required liquid-quality parameters, installation, signal interface, quantity, destination and project stage.