Home›Solutions›One-stop instrumentation for liquid-cooled data centers
Data center liquid cooling solution

One-stop instrumentation for liquid-cooled data centers

A project-facing instrumentation path for CDU systems, load banks and cold-plate flow and thermal-resistance testing.

CDU · LOAD BANK · COLD PLATE TEST
PRIMARY SIDESECONDARY SIDE
CDUcoolant distribution
FLOW
PRESSURE
TEMPERATURE
COOLANT QUALITY
FMX300 flowmeter source product imageFlow
P202 temperature transmitter source product imageTemperature
Digital coolant-quality sensor source product imageCoolant quality
Direct answer

The system in one paragraph

FUNEL helps EPC contractors, MEP contractors, CDU integrators and equipment OEMs coordinate the instrumentation package around the actual liquid-cooling circuit. Public information here shows the application scope and product paths; detailed system drawings, full model combinations and project quotations are prepared after the project requirements are reviewed.

01 · Project brief

Inputs required before model selection.

01

Project role

EPC, MEP contractor, CDU integrator, test-equipment builder or OEM

02

Application

CDU integrated system, load bank, cold-plate flow test or thermal-resistance validation

03

Monitoring points

Flow, pressure, supply and return temperature, pH, conductivity and turbidity

04

Integration

Pipe size, media, pressure, temperature, installation, power and 4–20 mA / RS485 / Modbus requirements

02 · Measurement map

Connect each point to an operating decision.

StageObjectiveParameters to considerSelection note
CDU systemMonitor the primary and secondary coolant circuitsFlow, pressure, supply and return temperature, coolant qualityThe exact locations and model combination depend on the CDU layout and coolant circuit.
Load bankValidate simulated CPU or rack-loop performanceInlet and outlet flow, pressure and temperatureConfirm pipe size, range, response and control-system interface before selection.
Cold-plate testValidate flow and thermal resistanceOperating flow, differential pressure, fluid and ambient temperature, pH, conductivity and turbidityUse the test section and conditioning section shown in the project material as the starting point.
03 · System architecture

Design the measurement, installation and data path together.

01

Define the project circuit

Share the P&ID, CDU layout, test-bench drawing or monitoring-point list so instrument locations can be reviewed against the actual circuit.

02

Match each measurement

Select flow, pressure, temperature and liquid-analysis instruments from the required range, media, installation and signal interface.

03

Coordinate the package

FUNEL can consolidate the agreed models, accessories, interfaces and documentation into one project quotation.

04

Keep detailed design controlled

Full wiring, detailed model combinations and project-specific selection tables are released after the application and customer are confirmed.

Products for this path

CDU Integrated System Solution

Products for primary and secondary loop monitoring.

TBY100 · Integrated compact temperature transmitter
TBY100

Integrated compact temperature transmitter

Supply and return temperature

P202 / PX202 / TH800 · Temperature and humidity transmitters
P202 / PX202 / TH800

Temperature and humidity transmitters

Temperature and ambient humidity

ADE3350 / ADP2450 / ADU1310 / ADG310 · Digital liquid-analysis sensors
ADE3350 / ADP2450 / ADU1310 / ADG310

Digital liquid-analysis sensors

pH, conductivity and turbidity

TDS210-B / TDS-7001G / PH6.5 / ASP-2330 · Analog liquid-analysis instruments
TDS210-B / TDS-7001G / PH6.5 / ASP-2330

Analog liquid-analysis instruments

Analog conductivity and pH

Products for this path

Data Center Load Bank Solution

Products for simulated CPU or rack-loop validation.

FLC420 / FVX260 · Turbine and vortex flowmeters
FLC420 / FVX260

Turbine and vortex flowmeters

Compact coolant-loop flow measurement

TBY100 · Integrated compact temperature transmitter
TBY100

Integrated compact temperature transmitter

Supply and return temperature

Products for this path

Cold Plate Flow and Thermal Resistance Test Solution

Products for flow, differential pressure, temperature and coolant-quality validation.

TBY100 · Integrated compact temperature transmitter
TBY100

Integrated compact temperature transmitter

Supply and return temperature

ADE3350 / ADP2450 / ADU1310 / ADG310 · Digital liquid-analysis sensors
ADE3350 / ADP2450 / ADU1310 / ADG310

Digital liquid-analysis sensors

pH, conductivity and turbidity

FAQ

Questions to resolve before quotation.

Who is this solution intended for?+

It is intended for data-center EPC contractors, MEP contractors, CDU integrators, test-equipment builders and OEMs that need a coordinated instrumentation package.

Can I receive the complete selection table immediately?+

The public page shows the application and product paths. Detailed drawings, complete model combinations and project quotations are prepared after the project requirements are reviewed.

What should I send for a project quotation?+

Send the P&ID or system drawing, media, pipe size, flow, pressure, temperature, required liquid-quality parameters, installation, signal interface, quantity, destination and project stage.

Discuss your liquid-cooling project

Tell us what you need. We will review the measurement points and product options; complete drawings and quotations follow requirement review.

Selected product options

Select products above, or describe your requirement below.

We use these details to respond to this project inquiry.

Email WhatsApp