254 nm UV absorbance measurement

PUVCOD-600 Compact UV254 COD and Turbidity Analyzer
A slim direct-immersion UV absorbance probe for continuous COD correlation with documented turbidity measurement, designed for tighter mounting spaces.
Verified product highlights
Compact Ø34 mm direct-immersion probe
COD correlation and turbidity measurement
Reagent-free continuous measurement
Automatic probe cleaning
4–20 mA, relays and Modbus RS485
Verified technical specifications
- Measurement principle
- 254 nm UV absorbance (SAC254) with COD correlation and turbidity measurement
- 5 mm path configuration
- COD 0–1000 mg/L; turbidity 10–1000 NTU
- 25 mm path configuration
- COD 0–100 mg/L; turbidity 10–300 NTU
- COD accuracy
- ±5% or ±1 mg/L, whichever is greater, with KHP standard solution
- Turbidity accuracy
- ±10%
- Repeatability
- ±5% with KHP standard solution
- Resolution
- COD 0.01 mg/L; turbidity 0.01 NTU
- Pressure rating
- ≤0.1 MPa
- Construction
- SUS316L standard; titanium-alloy seawater version; PUR cable
- Power supply
- 85–500 VAC or 9–36 VDC
- Outputs
- 3 × 4–20 mA; 3 configurable relays; Modbus RS485
- Operating temperature
- 0–45°C, non-freezing
- Probe dimensions
- Ø34 × 223 mm (5 mm path); Ø34 × 244 mm (25 mm path)
- Protection
- Probe IP68 / NEMA6P; transmitter IP66 / NEMA4X
- Cable
- 10 m standard; extendable to 100 m
Typical applications
Wastewater process
Monitor organic-load changes where a compact immersion probe fits the installation.
Plant inlet and outlet
Combine COD correlation and turbidity trends in one optical measurement point.
Surface-water stations
Use reagent-free optical monitoring in rivers, reservoirs and environmental stations.
Industrial process water
Integrate continuous organic-load and turbidity signals into project controls.
Confirm optical path, turbidity and correlation together
The two documented optical paths have different COD and turbidity ranges. Selection must be based on the actual water matrix, reference method, expected ranges, fouling risk and mounting space.
- 01Provide COD and turbidity ranges
- 02State the laboratory reference method
- 03Confirm fouling and automatic-cleaning needs
- 04Confirm mounting, cable, outputs and panel interface
Project documents
Request the configured datasheet, optical-path confirmation, installation arrangement and quotation after the application is reviewed.
Share your project requirement- Configured technical datasheet→
- Optical-path and range confirmation→
- Installation and cable schedule→
- Project quotation→
Tell us what you need to measure.
We will respond with a recommended configuration, supporting documentation and quotation.