HomeParametersORP selection center
ORP · Sensors and online systems

Select online ORP measurement by range, water matrix and system interface

Two supplied technical files support structured ±2000 mV and ±1000 mV sensor configurations plus an online system with 4–20 mA, relays and Modbus RS485. The files do not state commercial model numbers, so none are invented.

2structured product groups
±1000 / ±2000 mVverified ranges
≤0.6 MPasensor pressure
2real project records
01 · Start with the process

ORP selection needs more than one mV value

ORP depends on the oxidation-reduction system in the water, electrode condition, temperature, fouling and installation. Range, material, mounting, cable and control interface must be confirmed together.

01

Water and control objective

Identify disinfection, aeration, anoxic/anaerobic treatment, industrial reaction or outlet trend monitoring.

02

Normal and upset range

Provide normal operation, control setpoint and expected positive or negative peaks.

03

Temperature, pressure and mounting

Confirm continuous temperature, pressure, R3/4 or 3/4 NPT, insertion and maintenance access.

04

Controller and outputs

Specify an existing electrode input or a complete system with 4–20 mA, relays and Modbus RS485.

02 · Product architecture

Sensor series and online analyzer system

Both pages publish only values confirmed in the supplied Word files. Products without a commercial model are presented as verified configurations.

Neutral industrial ORP sensor from the supplied technical documentSensors and electrodes
ORP sensor seriesSensors and electrodes

Two source-verified sensor constructions cover ±2000 mV standard service and a ±1000 mV economy configuration. The supplied documents do not state commercial model numbers, so no model number is invented.

±2000 / ±1000 mV≤0.6 MPa10 m standard cable
Neutral online ORP analyzer controller and sensorOnline analyzer system
Online ORP configurationOnline analyzer system

A source-verified controller-and-sensor system for continuous ORP monitoring in municipal water, wastewater, surface water and industrial processes. The source file does not state a commercial model number.

±2000 mV±5 mV3 × 4–20 mA / RS485
04 · Common questions

Confirm this information before an inquiry

Why are commercial model numbers such as POP-500 not used here?+

The two current technical files do not state a commercial model number. A model shown in a historical case is not assumed to be identical to the current configuration.

Are the ±2000 mV and ±1000 mV configurations interchangeable?+

No. Their materials, temperature limits, dimensions and mounting threads differ.

Can an ORP sensor connect directly to a PLC?+

A conventional electrode needs a compatible controller; the source also describes an optional analog-to-digital module. The complete online system provides 4–20 mA and Modbus RS485.

Why are equipment brands absent from the case images?+

The real project setting and equipment count are retained while third-party brands, company names and nameplates are neutralized for public use.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.