HomeParametersAmmonia nitrogen selection
NH₄-N · Online ion-selective electrode

Select online ammonia nitrogen measurement by water matrix, range and compensation requirements

PINH3-900 and PINH3-500 both cover 0.1–3000 mg/L NH₄-N with integrated pH and temperature compensation; PINH3-900 also supports optional K⁺ measurement.

2online analyzer models
0.1–3000 mg/LNH₄-N range
0.01 mg/Lammonia resolution
3 × 4–20 mAanalog outputs
01 · Start with the duty

Confirm the real water matrix and ion-compensation requirement

Ion-selective electrode response depends on the water matrix, pH, temperature and interfering ions. Selection cannot rely on maximum range alone; the process point, potassium conditions, mounting and interfaces must be confirmed.

01

Water matrix and process point

State nitrification, aeration tank, industrial process, river or other duty and describe the sample.

02

Minimum, normal and peak

Provide minimum, normal, peak and alarm NH₄-N—not a single design value.

03

pH, temperature and potassium

Confirm pH, temperature, potassium interference and whether the PINH3-900 optional K⁺ measurement is required.

04

Mounting and interfaces

Confirm space, cable, power, 4–20 mA, relays, RS485, quantity and destination.

02 · Model architecture

PINH3-900 advanced compensation + PINH3-500 compact

Select by K⁺ compensation requirement, probe size, measuring range, outputs and available mounting space.

03 · Key specifications

Core PINH3 series technical parameters

Both models use ion-selective electrodes with integrated pH and temperature compensation, analog outputs, relays and Modbus RS485.

  1. 01NH₄-N range · 0.1–3000 mg/L
  2. 02Resolution · 0.01 mg/L; pH · 5–10
  3. 03Outputs · 3 × 4–20 mA / Modbus RS485
04 · Common questions

Confirm this information before an inquiry

How should I choose PINH3-900 or PINH3-500?+

Both have the same NH₄-N range. Compare PINH3-900 when optional K⁺ measurement or added ion compensation is required; choose PINH3-500 when a smaller probe is preferred and K⁺ measurement is not required.

Do both models measure pH and temperature?+

Yes. Both cover pH 5–10 and 0–40°C for integrated measurement and compensation.

How do the probe dimensions differ?+

PINH3-900 uses an Ø55 × 342 mm probe; PINH3-500 uses an Ø37 × 253 mm probe.

Which outputs are available?+

Both models provide three 4–20 mA outputs, three relays and Modbus RS485.

Tell us what you need to measure.

We will respond with a recommended configuration, supporting documentation and quotation.

By submitting, you agree that we may use this information to respond to your inquiry. Global supply · Sales excluded in India.

WhatsApp